SIB 0 OK 32 degrees C / 89 degrees F SIB 1 OK 33 degrees C / 91 degrees F SIB 2 OK 33 degrees C / 91 degrees F SIB 3 OK 33 degrees C / 91 degrees F SIB 4 OK 33 degrees C / 91 degrees F FPC 0 Top OK 37 degrees C / 98 degrees F FPC 0 Bottom OK 24 degrees C / 75 degrees F FPC 1 Top OK 25 degrees C / 77 degrees F FPC 1 Bottom OK 20 degrees C / 68 degrees F FPM GBUS OK 22 degrees C / 71 degrees F FPM Display OK 25 degrees C / 77 degrees F Fans Top Left Front fan OK Spinning at normal speed Top Left Middle fan OK Spinning at normal speed Top Left Rear fan OK Spinning at normal speed Top Right Front fan OK Spinning at normal speed Top Right Middle fan OK Spinning at normal speed Top Right Rear fan OK Spinning at normal speed Bottom Left Front fan OK Spinning at normal speed Bottom Left Middle fan OK Spinning at normal speed Bottom Left Rear fan OK Spinning at normal speed Bottom Right Front fan OK Spinning at normal speed Bottom Right Middle fan OK Spinning at normal speed Bottom Right Rear fan OK Spinning at normal speed Fourth Blower from top OK Spinning at normal speed Bottom Blower OK Spinning at normal speed Middle Blower OK Spinning at normal speed Top Blower OK Spinning at normal speed Second Blower from top OK Spinning at normal speed Misc CIP OK SPMB 0 OK SPMB 1 OK 3。4。5获得系统设备告警(SHOW CHASSIS ALARM) noc2004@BJ…BB1…T640》show chassis alarms No alarms currently active 3。4。6了解系统FPC运行情况(SHOW CHASSIS FPC) SLOTSTATE:可能的状态有:EMPTY/ONLINE/OFFLINE/PRESENT/UNRESPONSIVE 当在设备上新插入一块FPC时;系统会显示PRESENT状态表明该硬件已备路由器检测到;可以通过命令(见下)或按压FPC按钮的方式使其ONLINE。 Request chassis fpc slot x online'offline';若反复使用该命令后发现其状态为UNRESPONSIVE;通过更换此FPC的槽位仍不奏效;则可初步认为该板已损坏。请联系集成商或厂商作确认和返修。 noc2004@BJ…BB1…T640》 show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 0 0 0 0 0 0 1 Online 42 4 0 64 0 39 2 Online 42 4 0 32 1 39 3 Empty 0 0 0 0 0 0 4 Empty 0 0 0 0 0 0 5 Empty 0 0 0 0 0 0 6 Online 47 4 0 32 2 39 7 Empty 0 0 0 0 0 0 noc2004@BJ…BB1…T640》 show chassis fpc detail Slot 0 information: State Online Temperature 26 degrees C / 78 degrees F Total CPU DRAM 256 MB Total SRAM 56 MB Total SDRAM 1280 MB Start time 1999…01…01 00:06:15 UTC Uptime 5 days; 22 hours; 54 minutes; 45 seconds Slot 1 information: State Online Temperature 24 degrees C / 75 degrees F Total CPU DRAM 256 MB Total SRAM 28 MB Total SDRAM 640 MB Start time 1999…01…01 00:06:15 UTC Uptime 5 days; 22 hours; 54 minutes; 45 seconds 3。4。7路由引擎状态检测(SHOW CHASSIS ROUTING…ENGINE) 该命令提供系统管理员路由模块的工作状态/利用率:默认状态是SLOT0为主用;SLOT1为备用;可以通过以下命令将备用模块切换到主用状态: REQUEST SYSTEM ROUTING…ENGINE MASTER NOTE:应用该命令可直接导致转发数据中断一段时间(路由器重新确认主备关系的时间+路由协议重新收敛时间) 可以通过连接路由模块的仿真终端获得更多的诊断信息。在多数RE的返修案例中;很多是由于路由模块无法正常启动所至(内部FLASH或HARDDISK)损坏。 如何改变路由模块的启动顺序:可以通过仿真终端在路由模块启动时刻改变其启动顺序(默认为:外部FLASH……》内部FLASH……》内部HARDDISK)。当启动至BOOT:时可键入0:wd(1;a)kernel这样路由模块可从内部HARDDISK启动。 noc2004@BJ…BB1…T640》 show chassis routing…engine Routing Engine status: Slot 0: Current state Master Election priority Master Temperature 34 degrees C / 93 degrees F DRAM 2048 MB Memory utilization 11 percent CPU utilization: User 1 percent Background 0 percent Kernel 5 percent Interrupt 0 percent Idle 94 percent Model RE…3。0 Serial ID P10865704208 Start time 1999…01…01 00:04:43 UTC Uptime 5 days; 22 hours; 56 minutes; 17 seconds Load averages: 1 minute 5 minute 15 minute 0。00 0。03 0。01 Routing Engine status: Slot 1: Current state Backup Election priority Backup Temperature 34 degrees C / 93 degrees F DRAM 2048 MB Memory utilization 10 percent CPU utilization: User 0 percent Background 0 percent Kernel 0 percent Interrupt 0 percent Idle 100 percent